tag:blogger.com,1999:blog-2764966620291645022024-02-01T21:40:10.069-08:00..:: TAACSA ::...:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.comBlogger18125tag:blogger.com,1999:blog-276496662029164502.post-59319383664986377062019-07-16T15:56:00.000-07:002019-07-16T15:56:32.315-07:00Placas de advertencia en bronce o fierro fundido<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiTxWFGWoCsMFT7d-DTd5fUHtIZh4pDXvrEacui6ce0RsAQCntCtJyzkmBG8Q3fmdZqo5qbYKWvAZDM3ufBOy_2MMLfIQq9dZLHxCFv23aS9Sz1lYNXnqEqIO8FH4JKOQNrOYVzszY4sAIS/s1600/Placas+de+Advertencia.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" data-original-height="1600" data-original-width="1242" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiTxWFGWoCsMFT7d-DTd5fUHtIZh4pDXvrEacui6ce0RsAQCntCtJyzkmBG8Q3fmdZqo5qbYKWvAZDM3ufBOy_2MMLfIQq9dZLHxCFv23aS9Sz1lYNXnqEqIO8FH4JKOQNrOYVzszY4sAIS/s640/Placas+de+Advertencia.jpg" width="496" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-42895246375696774152019-07-15T15:24:00.000-07:002019-07-15T15:24:50.495-07:00Cable de Media y Alta Tensión XLPE<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg-nH1_2eTbOc_OSmZOu-1cB-yoviShET078eKLDprnUMW_K7FIOtCU8nNWtlN7qLA3VsCtj8Mt_ZvSkd1G6lN_99zcuGn7XZj3Ko-3fCVaAKEwS9quziaHXdteIOBMxLDnZ77uc9cc4ewk/s1600/XLP1.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" data-original-height="1600" data-original-width="1238" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg-nH1_2eTbOc_OSmZOu-1cB-yoviShET078eKLDprnUMW_K7FIOtCU8nNWtlN7qLA3VsCtj8Mt_ZvSkd1G6lN_99zcuGn7XZj3Ko-3fCVaAKEwS9quziaHXdteIOBMxLDnZ77uc9cc4ewk/s640/XLP1.jpg" width="494" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-6088601507429139132019-07-12T10:38:00.000-07:002019-07-12T10:38:03.501-07:00Analizadores y medidores de calidad de energía power pad III modelo 8336<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjyjd2uP2DG1NohfiHLpOc2q18X3fEFTNe1uVB5gnmFxXUOE2hnRPZJJGzYTxL8dpPTcr4r1JQ7APmBQRQpv90ipzYIUrHH3d1OTOUBLTdv6T_a_XV7VXkSOugmFW45K6bA4_8hNRYMon_0/s1600/AMCE-8336-ss.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" data-original-height="1600" data-original-width="1243" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjyjd2uP2DG1NohfiHLpOc2q18X3fEFTNe1uVB5gnmFxXUOE2hnRPZJJGzYTxL8dpPTcr4r1JQ7APmBQRQpv90ipzYIUrHH3d1OTOUBLTdv6T_a_XV7VXkSOugmFW45K6bA4_8hNRYMon_0/s640/AMCE-8336-ss.jpg" width="496" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-85083642412417662322019-07-10T09:14:00.000-07:002019-07-10T09:14:39.237-07:00Detector de alta tensión de CA sin contacto modelo 275HVD<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh9n2mucBtiPzL7tgfPQGQ8d27jI0GzVk56MI_wA88wLwzSTYkyYE9ZD0HeB1l9dXEq8UlpzHIPBuPiTJKVeIxIfsGwU3SYnN5UxRMMjnEVh1WdASbHHUzUFYoWxEyl0BU4BAQdyNCdeulD/s1600/119-aemc-detector-voltaje-s.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" data-original-height="1600" data-original-width="1232" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh9n2mucBtiPzL7tgfPQGQ8d27jI0GzVk56MI_wA88wLwzSTYkyYE9ZD0HeB1l9dXEq8UlpzHIPBuPiTJKVeIxIfsGwU3SYnN5UxRMMjnEVh1WdASbHHUzUFYoWxEyl0BU4BAQdyNCdeulD/s640/119-aemc-detector-voltaje-s.jpg" width="492" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-72255533111311294262019-02-13T15:12:00.002-08:002019-02-13T15:12:24.406-08:00Transformadores de Distribución y Potencia<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg9xeR_tRROZkoXAkXwcJokt8h_kk40MsmGzfg1byNfJ0e41YTbsoXQVeauW2CkCMCZlHV83kpggRSwSebngSWixKqJWS1Twim2PWGk5lWaX2445MFcKOqJE3lBY8aLGP5o_t2Xvjl8VHfg/s1600/prolec.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" data-original-height="1600" data-original-width="1238" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEg9xeR_tRROZkoXAkXwcJokt8h_kk40MsmGzfg1byNfJ0e41YTbsoXQVeauW2CkCMCZlHV83kpggRSwSebngSWixKqJWS1Twim2PWGk5lWaX2445MFcKOqJE3lBY8aLGP5o_t2Xvjl8VHfg/s640/prolec.jpg" width="495" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-14521557621734955112017-06-27T09:06:00.000-07:002017-06-27T09:06:23.431-07:00<span class="hs_cos_wrapper hs_cos_wrapper_meta_field hs_cos_wrapper_type_rich_text" data-hs-cos-general-type="meta_field" data-hs-cos-type="rich_text" id="hs_cos_wrapper_post_body"></span><br />
<h2>
<strong> </strong></h2>
<h2>
<strong> <div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiiyAfQusomFaHIpKzAv_pNQMTdXxDY41sJBUCtC1LnyrbXY1zXfhAKbPSDhMxTGgtXh6DsHblgYXfGYF31w5RbJiyEuYrzuN07z4oFNxactNAQoQWK20ebR_M9TnnMuVp7olI9tG7-TytE/s1600/pararrayos.jpg" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" data-original-height="948" data-original-width="1000" height="604" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiiyAfQusomFaHIpKzAv_pNQMTdXxDY41sJBUCtC1LnyrbXY1zXfhAKbPSDhMxTGgtXh6DsHblgYXfGYF31w5RbJiyEuYrzuN07z4oFNxactNAQoQWK20ebR_M9TnnMuVp7olI9tG7-TytE/s640/pararrayos.jpg" width="640" /></a></div>
</strong></h2>
<h2>
<strong>¿Qué es </strong><strong>el Sistema 3000 (Dynasphere) de Erico?</strong></h2>
<span style="font-weight: 400;">El sistema Dynasphere 3000 de Erico consiste en un pararrayos dinámico que sirve para <strong>proteger las instalaciones de descargas atmosféricas (rayos)</strong> generados durante tormentas eléctricas.</span><br />
<br />
<span style="font-weight: 400;">Cuenta con una punta
Franklin mejorada con un domo semi-esféricc (patentado por Erico) que
se encuentra acoplado capacitivamente al campo eléctrico para proteger
ciertas áreas en caso de una descarga atmosférica. </span><br />
<br />
<span style="font-weight: 400;">Cuando el voltaje es lo
suficientemente alto entre domo y punta, se crea un arco a través del
entrehierro entre la esfera y la punta aterrizada. Dicho arco provee <strong>dos grandes beneficios:</strong></span><br />
<ul>
<li><span style="font-weight: 400;"><strong>Genera un gran número de electrones libres</strong> necesarios para iniciar una trayectoria ionizada ascendente.</span></li>
</ul>
<ul>
<li><span style="font-weight: 400;"><strong>Genera un incremento “fijo” en el campo eléctrico</strong>
sobre la terminal aérea, lo cual otorga la energía adicional para
iniciar y convertir un líder ascendente con la velocidad de propagación
adecuada.</span></li>
</ul>
<br /><br />
<h2>
<strong>Ventajas del sistema </strong><strong>Sistema 3000 (Dynasphere)</strong></h2>
<span style="font-weight: 400;">Algunos de los beneficios que puedes obtener de la instalación de este sistema son:</span><br />
<ul>
<li><span style="font-weight: 400;">El lider ascendente generado <span style="font-weight: 400;">a</span><span style="font-weight: 400;"> partir de la</span><span style="font-weight: 400;"> punta</span><span style="font-weight: 400;"> intercepta </span>al rayo en un<span style="font-weight: 400;">a distancia que se traduce en una </span><span style="font-weight: 400;">área</span> de cierto radio, lo cual asegura una <strong>completa protección </strong> dentro de este rango.<br /></span></li>
<li><span style="font-weight: 400;"><strong>El cable patentado por Erico</strong>,
sirve como conductor de bajada para una mayor protección para la
estructura, lo cual ayuda a que el rayo no pase a la misma debido a su
aislamiento.<br /></span></li>
<li><span style="font-weight: 400;">Gracias al <strong>diseño de domo</strong> de este sistema de Erico, no se genera corriente espacial corona que inhibe la intercepcion del rayo<span style="font-weight: 400;">.</span><br /></span></li>
<li><span style="font-weight: 400;">Mayor seguridad, ya que el cable provee una mayor protección y<strong> ayuda a que la descarga llegue a tierra sin causar daños a los equipos</strong> eléctricos a su alrededor.<br /></span></li>
<li><span style="font-weight: 400;">Si se realiza un buen mantenimiento a los equipos, estos pueden<strong> durar de 20 a 30 años.</strong><br /></span></li>
<li><span style="font-weight: 400;">Con el plan de proteccion de seis puntos se evita daños a las tarjetas o demás equipos, lo que <strong>disminuye la necesidad de reemplazos</strong> constantes de partes o equipos completos.<br /></span></li>
<li><span style="font-weight: 400;">Erico brinda directamente la <strong>capacitación al personal</strong> que va a instalar el sistema.<br /></span></li>
<li><span style="font-weight: 400;">Esta capacitación se proporciona en cualquier lugar de la República Mexicana sin costo alguno.<br /></span></li>
<li><span style="font-weight: 400;">Después de la venta de los equipos Erico, <strong>el proveedor hace una revisión de la instalación</strong> del sistema para hacer válida la garantía.<br /></span></li>
<li><span style="font-weight: 400;">La <strong>garantía</strong> del Sistema Dynasphere 3000 es<strong> de 10 años.</strong></span></li>
</ul>
<br /><br />
<h2>
<strong>Componentes del Sistema 3000 de Erico</strong></h2>
<span style="font-weight: 400;">Este sistema de la marca Erico está compuesto por distintas partes:</span><br />
<ul>
<li><strong>Eritech Dynasphere:</strong><span style="font-weight: 400;"> Es la terminal de comportamiento dinamico que cuenta con una punta Franklin optimizada.</span></li>
</ul>
<ul>
<li><strong>Conductor de bajada Eritech Ericore:</strong><span style="font-weight: 400;"> Es el conductor de bajada.<br /></span></li>
<li><strong>Terminal superior Eritech Ericore:</strong><span style="font-weight: 400;"> Es un kit de terminal superior para realizar la conexion del conductor de bajada y Dynasphere<span style="font-weight: 400;">.</span><br /></span></li>
<li><strong>Terminal inferior ERITECH ERICORE: </strong><span style="font-weight: 400;">Es un kit de materiales para realizar la conexion del conductor de bajada a la varilla central del sistema de disipacion.<br /></span></li>
<li><span style="font-weight: 400;"><strong>Acoplador en línea:</strong> Permite acoplar el mastil de FRP a mastil de aluminio.<br /></span></li>
<li><strong>Anillo de anclaje: </strong><span style="font-weight: 400;">Es la pieza con la que se conectan los kits de retenidas.<br /></span></li>
<li><strong>Kit de retenidas:</strong><span style="font-weight: 400;"> Se utilizan para detener la terminal aérea del sistema 3000.<br /></span></li>
<li><strong>Contador de eventos de descargas atmosféricas:</strong><span style="font-weight: 400;"> Es una contador electromecanico que permite registrar los eventos atmosféricos que intercepta la Dynasphere.<br /></span></li>
<li><strong>Mástiles de FRP: </strong><span style="font-weight: 400;">Sostiene la dynasphere, la cual puede medir de 2 a 4.6 mts y está fabricado de un material aislante.<br /></span></li>
<li><strong>Base de placa: </strong><span style="font-weight: 400;">Base que sostiene lo que es mástil de FRP o toda la terminal aérea.<br /></span></li>
<li><strong>Mástil de aluminio:</strong><span style="font-weight: 400;"> Es un elemento que sostiene lo que es la Dynasphere, el cual puede medir 3, 4, 5 o 6 mts y está fabricado de aluminio.</span></li>
</ul>
<br />
<h2>
<strong>Consideraciones con el Sistema 3000 de Erico</strong></h2>
<span style="font-weight: 400;">Algunos factores que hay que tener en cuenta al instalar y utilizar este sistema de la marca Erico son:</span><br />
<ul>
<li><span style="font-weight: 400;">Al terminar de realizar la instalación, es <strong>necesario realizar un mantenimiento anual para poder hacer válida la garantía.</strong> Dicho mantenimiento consiste en revisar que los conectores y la terminal aérea se encuentren en buen estado.<br /></span></li>
<li><span style="font-weight: 400;">En caso de haber un evento en el sistema 3000 hay que <strong>verificar la terminal aérea</strong> posterior al evento para revisar cualquier posible daño y reportarlo.<br /></span></li>
<li><span style="font-weight: 400;">Si se llega a encontrar algún daño en el sistema hay que<strong> llamar al instalador para su apoyo en la gestión de la garantía</strong> y/o reparación con el proveedor.<br /></span></li>
<li><span style="font-weight: 400;">También existe un Sistema 2000 de Erico, pero cuenta con una menor capacidad de protección.</span></li>
</ul>
<br /><br />
<span style="font-weight: 400;">Esperamos que este artículo te sea de
utilidad para conocer los grandes beneficios de seguridad para tu
proyecto en este sistema de </span><a href="http://taacsa.com/index.php/biblioteca/item/sistema-3000"><span style="text-decoration: underline;"><span style="font-weight: 400;">productos Erico</span></span></a><span style="font-weight: 400;">.</span><br />
.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-92194903110438746172012-09-27T07:17:00.005-07:002017-06-27T08:59:06.528-07:00Sistema 3000 Pararrayos Dynasphere<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi-yBQjlrk6bI2kXfe77ExBIg4zueN7yRWk_YyRElE63T_59E4nxVpKdl66XV5xA9kuNTKuQ7OWToD3VQyvACY4bYPIXQ7BFECepf4xaRMlGCkfN_kfJ7LFLaTgQ5bq3g3eSA2CBU4Xi3N-/s1600/kit+pararrayos+dynasphere-ericore+(3).png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi-yBQjlrk6bI2kXfe77ExBIg4zueN7yRWk_YyRElE63T_59E4nxVpKdl66XV5xA9kuNTKuQ7OWToD3VQyvACY4bYPIXQ7BFECepf4xaRMlGCkfN_kfJ7LFLaTgQ5bq3g3eSA2CBU4Xi3N-/s640/kit+pararrayos+dynasphere-ericore+(3).png" width="500" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com1tag:blogger.com,1999:blog-276496662029164502.post-10149220248342033802012-09-26T08:44:00.000-07:002012-09-26T08:44:15.968-07:00Dipolo Corona<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhMAu1q4FzMOKvGnplwP7N697yo-rFUMX6DcboK94cZkIqoC9eAdLe6dD7Hb8AYh10XYMBDITyIAIyjB0RJrayY0ZZsID26laSkVlHpfzDYj4KfVb5NpI1fB6mjZopckFUQf1jTwE7vJi4-/s1600/kit+pararrayos+con+fondo.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhMAu1q4FzMOKvGnplwP7N697yo-rFUMX6DcboK94cZkIqoC9eAdLe6dD7Hb8AYh10XYMBDITyIAIyjB0RJrayY0ZZsID26laSkVlHpfzDYj4KfVb5NpI1fB6mjZopckFUQf1jTwE7vJi4-/s640/kit+pararrayos+con+fondo.png" width="500" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-36734010146765597262012-09-25T12:48:00.000-07:002012-09-25T12:48:27.779-07:00CADWELD PLUS <div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEggTPg6eX1-IAUZvi7dDQnR_-fb3roNmxI8-e1XmTmdyFnEjfXvG21TgZDYMDyp90XP6I-thD0QtOnj2TrQhJGtab0ijkoJF4T8VD9CErtiY6q3M_VV8KXNL8to_B2UFsNXbQHQjZeVC8o1/s1600/cadweld-plus.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEggTPg6eX1-IAUZvi7dDQnR_-fb3roNmxI8-e1XmTmdyFnEjfXvG21TgZDYMDyp90XP6I-thD0QtOnj2TrQhJGtab0ijkoJF4T8VD9CErtiY6q3M_VV8KXNL8to_B2UFsNXbQHQjZeVC8o1/s640/cadweld-plus.png" width="496" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-16149626807219908092012-09-25T09:06:00.003-07:002012-09-25T12:48:49.335-07:00GEM Cemento Conductivo Para Sistemas de Tierras<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgsKkmqOJdiKoCaQO2wiK2JtGcGXMsuIXfEerZU8Kgj-vIk3FHyr6OC6lw0StGV_OsuUGEgmlLAyqiOIjD4uy5hrIE7YZkBP39uC37BmecA9_5_dv3_VPQaisQE-nCtKLlD6lJLZsSkRyQ0/s1600/gem.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgsKkmqOJdiKoCaQO2wiK2JtGcGXMsuIXfEerZU8Kgj-vIk3FHyr6OC6lw0StGV_OsuUGEgmlLAyqiOIjD4uy5hrIE7YZkBP39uC37BmecA9_5_dv3_VPQaisQE-nCtKLlD6lJLZsSkRyQ0/s640/gem.png" width="472" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-36343043357363629182012-09-17T15:41:00.000-07:002012-09-17T15:41:50.535-07:00Gabinete Derivador<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEihbCtboFpYN234TbDJC1MYy3LGuvVd-ElrLZkqJrGsFlb63I_Gmr0Y_TGBmDhRbCqyHLgPfmJrf9_XgljABis2O-SWoYGZpHs3ZdytxFXDSy7OwXe8ZTM30YizDbBTW1bWaIeHC-7QV-yW/s1600/SECTER-FLYER-1.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="320" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEihbCtboFpYN234TbDJC1MYy3LGuvVd-ElrLZkqJrGsFlb63I_Gmr0Y_TGBmDhRbCqyHLgPfmJrf9_XgljABis2O-SWoYGZpHs3ZdytxFXDSy7OwXe8ZTM30YizDbBTW1bWaIeHC-7QV-yW/s320/SECTER-FLYER-1.png" width="226" /></a></div>
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj7VtBmUGYOPX4FgOVdCAYbehHlAriO0fFEFpw5oS8LzIFCnOiGE4LJYieE_TfBZEXhWvajtcSjGtNZOzTvAXG8wZaESJxZPcA5ai93IfGKPChJzlj25PG-DgMMTHoI_x78G2hogkvDDXKE/s1600/SECTER-FLYER-2.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="320" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj7VtBmUGYOPX4FgOVdCAYbehHlAriO0fFEFpw5oS8LzIFCnOiGE4LJYieE_TfBZEXhWvajtcSjGtNZOzTvAXG8wZaESJxZPcA5ai93IfGKPChJzlj25PG-DgMMTHoI_x78G2hogkvDDXKE/s320/SECTER-FLYER-2.png" width="227" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com1tag:blogger.com,1999:blog-276496662029164502.post-74508024860216925842012-09-14T13:56:00.002-07:002012-09-14T13:56:51.399-07:00Cadweld Productos para Sistemas de Tierra<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj0nXCjx4mxy5LMfKYNfDwExhotNO3PrkIcHn0-6xGK1EaZixFWXanI4vScTp_pigclHEHxHOv6qPVNuLLdEkF3FBDOe1Akgm6P-8A0EbVY22x28eXk5gWP4bojYEUhxWP_fE2qSnZ2Fnpc/s1600/1CADWELD+AND+GROUNDING.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEj0nXCjx4mxy5LMfKYNfDwExhotNO3PrkIcHn0-6xGK1EaZixFWXanI4vScTp_pigclHEHxHOv6qPVNuLLdEkF3FBDOe1Akgm6P-8A0EbVY22x28eXk5gWP4bojYEUhxWP_fE2qSnZ2Fnpc/s640/1CADWELD+AND+GROUNDING.png" width="481" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-69359799524758227152012-09-14T13:43:00.002-07:002012-09-14T13:43:38.093-07:00Plan de Protección de 6 Puntos<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgQMfNPFvBv9GecVH6XWw-OkjxRjBlljvTec91_qSOJ3-BeqNscKiV34WThVxyfK_KsadBi9olpDVhbbBdv0KpMUZ5eaMF7LlRxN7j2w-J0ywqgNmHjQJVDJvmC_mTvx9O5WyhvVoAGA5KL/s1600/Plan+Protecci%C3%B3n++6+puntos.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="331" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgQMfNPFvBv9GecVH6XWw-OkjxRjBlljvTec91_qSOJ3-BeqNscKiV34WThVxyfK_KsadBi9olpDVhbbBdv0KpMUZ5eaMF7LlRxN7j2w-J0ywqgNmHjQJVDJvmC_mTvx9O5WyhvVoAGA5KL/s400/Plan+Protecci%C3%B3n++6+puntos.png" width="400" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-49963739879856995052012-09-14T13:10:00.001-07:002012-09-14T13:20:38.209-07:00Abrazadera ISN-ISSP<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiZDAC7TFMeeYfBWJEajI0UsKny0vG3hB4_wRKyu3chl04Yhw7v0zr1WXPpPykID1zn7XvFVlIG4x9WqKIKqGEuxHRPF6mitK95-dHwM6lo_aXbxxaab13bKY4PAokgIP3AG0FXN3rbHd5y/s1600/ISN.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="320" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiZDAC7TFMeeYfBWJEajI0UsKny0vG3hB4_wRKyu3chl04Yhw7v0zr1WXPpPykID1zn7XvFVlIG4x9WqKIKqGEuxHRPF6mitK95-dHwM6lo_aXbxxaab13bKY4PAokgIP3AG0FXN3rbHd5y/s320/ISN.png" width="247" /></a></div>
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjmu7cw6pzJGimg94XHsiuFpi1SupK0sq5Qvwnra6b3W6Hj9HQjieTdoMyou6r1-x_yGqyL2bszm3K_NMiglfDCumKAuIIrCWaZw4CFRRkq6GhgMJnIVhauf5z43jMHeTbkaPmbU_387XdT/s1600/ISSP.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="320" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEjmu7cw6pzJGimg94XHsiuFpi1SupK0sq5Qvwnra6b3W6Hj9HQjieTdoMyou6r1-x_yGqyL2bszm3K_NMiglfDCumKAuIIrCWaZw4CFRRkq6GhgMJnIVhauf5z43jMHeTbkaPmbU_387XdT/s320/ISSP.png" width="247" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-81198476722195789102012-07-28T07:51:00.005-07:002012-09-14T13:20:51.586-07:00Eritech Critec PEC<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiOh7k7PEytgok-aPoT39U8sjXsPudmJr3f6TZsdGeF5oJmIO_VOf73AuYmKeO3w1CdI-pdWWuxntEzNOiQ8PrBr3RRJ-MJy4ToBQK-vSO7O0S-IdzUwqKQ8Qx-WMNvnJO2hx75mvH6Q6Ov/s1600/pec.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiOh7k7PEytgok-aPoT39U8sjXsPudmJr3f6TZsdGeF5oJmIO_VOf73AuYmKeO3w1CdI-pdWWuxntEzNOiQ8PrBr3RRJ-MJy4ToBQK-vSO7O0S-IdzUwqKQ8Qx-WMNvnJO2hx75mvH6Q6Ov/s640/pec.png" width="486" /></a></div>
<br />.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-91453094789432387262012-04-25T14:48:00.000-07:002012-09-14T13:20:22.543-07:00Tierras Físicas (3era. Parte)<div style="text-align: center;">
<span style="color: #3d85c6; font-family: Verdana,sans-serif; font-size: x-large;"><b>Poner a tierra para reducir las diferencias de potencial.</b></span></div>
<span style="font-family: Verdana,sans-serif;"> <span style="color: #3d85c6; font-size: large;"><b>T</b></span>oda estructura metálica conductiva expuesta que puede ser tocada por una persona, debe ser conectada a tierra (aterrizada). La mayoría de los equipos eléctricos se aloja en el interior de gabinetes metálicos y si un conductor energizado llega a entrar en contacto con éstos, el gabinete también quedará temporalmente energizado. La conexión a tierra de los gabinetes y de todas las partes metálicas de la estructura es para asegurar que, si tal falla ocurriese, entonces el potencial sobre todas las estructuras metálicas conductivas expuestas sea virtualmente el mismo. En otras palabras, si conectamos todas las partes metálicas de la estructura y gabinetes metálicos de equipos a tierra, esta conexión igualará el potencial en el interior del local, de modo que las diferencias resultantes son mínimas. De este modo, se crea una «plataforma» equipotencial.</span><br />
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh13jhj6s8JaKBE_GxbmvFfWCQWYbKRgiWGetnrPrAACW5c2iI6z8e23ERJicks9lIVuk-kzBRqRCvsLfEYhFc1UfvexKVyWz2SjJiZzg7pNNNiy_-OCAUqgGUDEqYFT54qiOlupUvSFr3k/s1600/puesta+tierra.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="320" oda="true" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEh13jhj6s8JaKBE_GxbmvFfWCQWYbKRgiWGetnrPrAACW5c2iI6z8e23ERJicks9lIVuk-kzBRqRCvsLfEYhFc1UfvexKVyWz2SjJiZzg7pNNNiy_-OCAUqgGUDEqYFT54qiOlupUvSFr3k/s320/puesta+tierra.png" width="319" /></a></div>
<br />
<span style="font-family: Verdana,sans-serif;"> Si una persona está en contacto de manera simultanea con dos piezas diferentes de una estructura metálica expuesta, el conductor de conexión a tierra deberá garantizar que la persona no reciba un choque eléctrico, haciendo que la diferencia de potencial entre los equipos sea insuficiente para que esto ocurra. El mismo principio se aplica en el interior de grandes subestaciones eléctricas, industrias y casas. En industrias, la conexión a tierra de estructuras metálicas expuestas garantiza que una falla eléctrica a la carcasa de la máquina no genere una diferencia de potencial entre ella y la estructura metálica puesta a tierra en una máquina adyacente. En la casa, la conexión a tierra garantiza que si ocurriese una falla a la cubierta metálica de una máquina lavadora u otro electrodoméstico, cualquier persona que estuviese tocando en el momento de falla simultáneamente uno de estos equipos y el gabinete metálico, no experimentaría un choque eléctrico. Un caso muy especial lo tenemos en las instalaciones de algunas secciones de los hospitales (como los quirófanos y salas de cuidados intensivos).</span><br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEignTHd5C7vMLuQUpnAcgFhD2u19S0CpLS2RbQyritWmZk2svioxzOcf3h_q2diw09S6jls9wQ4jNT9WtVdpgFNRwGqBnSwOrp2pKsNDrLRxNGAJ-zGk9UfAPkP94s_LBy9mOQsSwg6RDQz/s1600/cuidados+intensivos.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="192" oda="true" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEignTHd5C7vMLuQUpnAcgFhD2u19S0CpLS2RbQyritWmZk2svioxzOcf3h_q2diw09S6jls9wQ4jNT9WtVdpgFNRwGqBnSwOrp2pKsNDrLRxNGAJ-zGk9UfAPkP94s_LBy9mOQsSwg6RDQz/s320/cuidados+intensivos.png" width="320" /></a></div>
<br />
<span style="font-family: Verdana,sans-serif;"> En estos lugares, los pacientes sometidos a una intervención quirúrgica o en estado de gravedad, son eléctricamente susceptibles, y una pequeña corriente de tan solo 20 microamperios puede ser fatal. Esta corriente tan pequeña solo necesita una pequeña diferencia de potencial para hacerla circular, es por esto que en las instalaciones eléctricas de estos lugares se deben tener dos consideraciones muy importantes:</span><br />
<span style="font-family: Verdana,sans-serif;"> 1.- EL PACIENTE SIEMPRE DEBE ESTAR CONECTADO A TIERRA</span><br />
<span style="font-family: Verdana,sans-serif;"> 2.- EL EQUIPO CONECTADO O NO A UN PACIENTE SIEMPRE DEBE ESTAR CONECTADO A TIERRA</span><br />
<br />
<span style="font-family: Verdana,sans-serif;"><span style="color: #3d85c6; font-size: large;"><b>Poner a tierra para reducir el ruido eléctrico.</b></span></span><br />
<br />
<span style="font-family: Verdana,sans-serif;">Una concepción errada muy popular es que el sistema de puesta a tierra opera sólo durante condiciones de falla. En realidad, también durante la operación rutinaria cumple ciertos roles vitales. Por ejemplo, muchas alimentaciones de potencia incluyen ahora una conexión a tierra, a través de la cual se dispersan al terreno corrientes residuales y corrientes armónicas. La creencia sostenida previamente de que estas corrientes podían ser conducidas a tierra sin consecuencias adversas, se reconoce ahora como falsa. Las corrientes que fluyen a tierra, de alguna manera deben retornar a la fuente, formando un circuito cerrado Estos crearán diferencias de potencial que, aunque pequeñas, causan ruido, zumbido, y posibles daños a equipo electrónico. El ruido eléctrico en los equipos electrónicos no son mas que pequeños voltajes que se montan en las señales, provocando sobre voltajes, como es sabido, el equipo electrónico funciona a base de señales voltajes y corrientes, por lo tanto una alteración de estas señales puede provocar por ejemplo información errónea en los equipos de procesamiento de datos, o en otros casos mala recepción de imágenes, etc. Una buena práctica de conexión a tierra eliminará la mayor parte de estas fallas en los equipos electrónicos sensibles.</span><br />
<br />
<span style="font-family: Verdana,sans-serif;"><span style="color: #3d85c6; font-size: large;"><b>Poner a tierra para disipar las corrientes de Rayo </b></span></span><br />
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi0xQFQznSSWWnOigs9S_MLQqn3r_jBCBjPHqlfGTmNzhmGEP4xQDTxG02DPD76MAM3THueM0ZBd8kI_89J_orLgJ5aXnc_C1KgyHyOX9jeLv9bO6ZnhQ2f3vrov0CeJlpYX8sANxhp8ZVp/s1600/centros+computo.png" imageanchor="1" style="clear: left; cssfloat: left; float: left; margin-bottom: 1em; margin-right: 1em;"><img border="0" height="203" oda="true" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEi0xQFQznSSWWnOigs9S_MLQqn3r_jBCBjPHqlfGTmNzhmGEP4xQDTxG02DPD76MAM3THueM0ZBd8kI_89J_orLgJ5aXnc_C1KgyHyOX9jeLv9bO6ZnhQ2f3vrov0CeJlpYX8sANxhp8ZVp/s320/centros+computo.png" width="320" /></a></div>
<span style="font-family: Verdana,sans-serif;">La descarga atmosférica conocida como rayo, es la igualación violenta de cargas de un campo eléctrico que se ha creado entre una nube y la tierra o, entre nubes. Una nube de tormenta puede contener unos 140 MWh de energía con voltajes hasta de 100 Mv. Esta energía es la que se disipa mediante los rayos, con corrientes pico que van de unos cuantos kA a unos 200 kA. Los rayos son señales eléctricas de alta frecuencia, gran potencial y alta corriente, Son de alta frecuencia por la elevada razón de cambio de la señal, de aproximadamente 1 us. Por ello, para dirigir a tierra las descargas atmosféricas se requiere de las técnicas para señales en altas frecuencias, es decir conductores de baja impedancia, en especial de muy baja inductancia. Por lo tanto, para disipar a tierra las corrientes de rayo, no solo debemos conservar un bajo valor de resistencia a tierra de los electrodos, sino debemos tener especial cuidado en los conductores empleados para este propósito. Los conductores planos, y los sistemas de electrodos de puesta a tierra de configuración radial son los mas recomendados para estas aplicaciones. </span><br />
<br />
<span style="color: #3d85c6; font-family: Verdana,sans-serif; font-size: large;"><b>Poner a tierra para disipar la electricidad estática</b></span><br />
<br />
<span style="font-family: Verdana,sans-serif;">Las cargas electrostáticas se crean en líquidos o polvos que tienen una rigidez dieléctrica elevada, y pueden llegar a ser de varios kilo volts de magnitud. La neutralización de esas cargas electrostáticas se logra uniendo todas las partes metálicas y dieléctricas utilizando la tierra como referencia de potencial cero. La mayor peligrosidad de las cargas electrostáticas se presenta en los lugares donde se manejan vapores y polvos combustibles o explosivos, por lo que las instalaciones metálicas que no estén destinadas a conducir energía eléctrica. Tales como cercas perimetrales y estructuras metálicas y maquinaria y equipo ubicados en zonas en donde se manejen, almacenen o transporten sustancias inflamables o explosivas, deben conectarse a tierra. </span><br />
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEghUF0KVFYu7B9U3UIyjo_980CM9t_ITCmLKARwKRmKLh6A1N4NXwfT_TvAawJ6wG3pRTUUj91H_gAKEtbmqOz_ryKi8dqdkU_Av77TH2Mckj7WV58TwlxpW1oSqaVoyZLGyI8-1G2Kyanz/s1600/norma+tierra+fisica.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" height="640" oda="true" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEghUF0KVFYu7B9U3UIyjo_980CM9t_ITCmLKARwKRmKLh6A1N4NXwfT_TvAawJ6wG3pRTUUj91H_gAKEtbmqOz_ryKi8dqdkU_Av77TH2Mckj7WV58TwlxpW1oSqaVoyZLGyI8-1G2Kyanz/s640/norma+tierra+fisica.png" width="562" /></a></div>
.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.comtag:blogger.com,1999:blog-276496662029164502.post-39946975808783867572012-04-05T09:11:00.000-07:002012-09-14T13:21:23.707-07:00Tierras Físicas (2nda. parte)Regresemos un poco a nuestras clases química. Aprendimos que el oro, la plata, el mercurio y el cobre tienen una alta resistencia a la corrosión. Los metales nobles como el cobre, son los cátodos cuando se combinan con metales menos nobles en presencia de agua (un electrolito), por lo tanto los menos nobles llegan a sacrificarse o a comportarse como ánodos. Para ser resistentes a la corrosión, el electrodo de tierra recubierto de cobre debe contar con la aprobación de la norma UL (Underwriter Laboratories. ¿Qué queremos decir con la aprobación UL? Sinifica que una varilla conductora debe tener su recubrimiento de cobre igual o mayor a 10 Mil [0.254 mm (0.010")], con el objeto de incrementar su tiempo de vida en el terreno.<br />
<br />
En la Especificación de CFE-56100-16 Electrodos para Tierras, menciona lo siguiente: 5.3 Adherencia de la cubierta: La cubierta se puede rayar o maltratar, pero en ninun caso, se debe desprender del núcleo. En la tabla de dimensiones de la misma especificación menciona: Electrodo ACE-16 Recubrimiento de cobre electrolítico espesor mínimo de 0.25 mm., de acuerdo a el Standard Specification for cooper Shet, Strip, Plate, and Rolled Bar ASTM B152/B152M-2006<br />
<br />
A continuación explicamos que es "Mil"<br />
<br />
10 Mil = 0.254 milímetros = 0.010 pulg.<br />
7 Mil = 0.1778 milímetros = 0.007 pulg.<br />
0.22 Mil = 0.00558 milímetros = 0.000219 pulg.<br />
<br />
La madre naturaleza sabe que nada que introduzcamos en el suelo durará para siempre, sin embargo LOS FABRICANTES en el ramo eléctrico deben su parte para determinar y especificar que una varilla de tierra recubierta de cobre tenga el mayor tiempo de vida útil.<br />
<br />
Consejos que le ayudarán a minimizar la corrosión:<br />
<br />
* Utilice sólo varillas con recubrimiento de cobre por electro depositación que cuenten con la aprobación UL, de manera que aseguren un mayor tiempo de vida y por lo tanto una operación confiable del sistema de tierra a través de los años.<br />
<br />
* Realice inspecciones de corrosión y pruebe sus sistemas de tierra anualmente.<br />
<br />
* No utilice relleno a base de carbón vegetal u otras sales que aceleren el proceso de corrosión de la varilla.<br />
<br />
* Compruebe que los metales que utilice en su sistema de tierra sean compatibles, no mezcle cable de cobre con cable de aluminio, sobre todo cuando se trate de conexiones enterradas.<br />
<br />
* No utilice conexiones mecánicas, use las conexiones exotérmicas sobre todo cuando los metales esten enterrados o en presencia de electrolitos.<br />
<br />
* No utilice varillas "revestidas" de cobre.<br />
<br />
Recuerde, la selección inicial del componente de una varilla es de vital importancia para lograr un sistema de tierra efectivo y de larga duración.<br />
<br />
Reporte tomado de: La revista "Horizonte electromecánico" págs. 8 y 9 por el Ing. Angel Alejandro Aké Santos <a href="mailto:apcie@prodigy.net.mx">apcie@prodigy.net.mx</a><br />
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhdWJuxUjPFKpMptRyeS9WcQmOmoW8OeXRyBtW2UfV5kzFuzOoBNF_tA6JczSu3FJl8md-gWMzmVt7XrikL8nqTXm_EpYIqar6waai-3jWZkL507v8rAFh3TZkqtgKbA6FO3D4nkc7K3QEI/s1600/001.gif" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" nda="true" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhdWJuxUjPFKpMptRyeS9WcQmOmoW8OeXRyBtW2UfV5kzFuzOoBNF_tA6JczSu3FJl8md-gWMzmVt7XrikL8nqTXm_EpYIqar6waai-3jWZkL507v8rAFh3TZkqtgKbA6FO3D4nkc7K3QEI/s1600/001.gif" /></a></div>
.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0tag:blogger.com,1999:blog-276496662029164502.post-16042706426460073242012-04-05T07:30:00.000-07:002012-09-14T13:21:41.881-07:00Tierras Físicas (1era. parte)¿Sabía usted que el recubrimiento de cobre de su varilla juega un papel muy importante en la duración de su sistema de tierra?<br />
<br />
Si su repuesta es: "no lo sé", "no estoy seguro" o aún "sé que el recubrimiento es de 5 Mils [0.127 mm (0.005)]", le sugerimos lea ésto:<br />
<br />
Cientos de personas mueren electrocutadas cada año y una cantidad no especificada de equipos costosos son dañados y se sufren interrupciones del servicio no proramados debido a una mala instalación en los sistemas de tierra con varillas que no cumplen en forma efectiva la función para la que están diseñadas. Un apropiado sistema de tierras en cualquier edificio, estructura o equipo eléctrico es esencial para proteger el equipo, así como a las personas que viven o trabajan en o cerca de las instalaciones.<br />
<br />
Cuando una varilla o electrodo instalada en el suelo ha perdido parte de su recubrimiento de cobre, la corrosión se inicia sobre el material metálico (coll roll), en éste momento la resistencia de contacto aumenta y la resistencia total a tierra de la red también. Cuando se presenta una falla eléctrica y se inyecta una corriente a la red, el producto de ésta por la resistencia a tierra crea una elevación de tensión que irá en aumento, cuando más crezca la resistencia a tierra, esta elevación lo hará también, poniendo en riesgo al equipo y a las personas .<br />
<br />
Por otro lado, la trayectoria de baja impedancia que debiera proporcionar un buen sistema de tierra, se pierde debido a la alta resistencia de contacto y en consecuencia el sistema debe ser rehabilitado. El cuerpo humano puede proveer en caso falla del sistema eléctrico, la trayectoria a tierra más directa si el sistema de tierra no está bien diseñado o si las interconexiones de protección están abiertas por motivo de corrosión. La gente suele estar entre la fuente de electricidad y el sistema de tierra y sin saberlo se convierte en parte de la trayectoria de la falla y corre el riesgo de electrocución.<br />
<br />
El buen funcionamiento de un sistema eléctrico depende de varios factores y uno de los más importantes, porque involucra tanto la protección del equipo como de personas, es el sistema de tierra. Uno de los componentes básicos en un sistema de tierra lo constituye la varilla o electrodo de tierra cobrizada. Este término define una película de cobre sobre la varilla base y éste es el elemento más importante que, dependiendo de su espesor y calidad de aplicación del cobre, determina la resistencia a la corrosión de la misma. El factor principal para determinar el tiempo de vida de un electrodo es precisamente su capacidad para soportar la corrosión. el departamento de Normatividad de corrosión subterránea en Estados Unidos realizó un estudio donde observó que hay una pérdida en peso de las varillas de tierras colocadas en 43 diferentes tipos de suelo durante un período de 8 a 13 años. El estudió concluyó que las varillas fabricadas con un recubrimiento de cobre de 7 mils o más, darán como resultado en los electrodos instalados una vida de servicio de 30 años.<br />
<br />
<div class="separator" style="clear: both; text-align: center;">
<a href="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgSPaPo_GVptunrNzPg2jVE6S2UC9Cjq0eaItZ7dwD8TqyI6KR1xI_dLp9N5jGsRa8ey-cBeUY_1fHm3XIk2gQk0NP94s64r9va3Iifa9EkL3ggcTrxgQwRNzf9GUHo0GmboYz_VioI0t6K/s1600/varilas.png" imageanchor="1" style="margin-left: 1em; margin-right: 1em;"><img border="0" src="https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEgSPaPo_GVptunrNzPg2jVE6S2UC9Cjq0eaItZ7dwD8TqyI6KR1xI_dLp9N5jGsRa8ey-cBeUY_1fHm3XIk2gQk0NP94s64r9va3Iifa9EkL3ggcTrxgQwRNzf9GUHo0GmboYz_VioI0t6K/s1600/varilas.png" /></a></div>
<div class="separator" style="clear: both; text-align: center;">
<br /></div>
.:: Terminales, Aislamientos, Accesorios y Conectores, S.A. ::.http://www.blogger.com/profile/04821457559626367132noreply@blogger.com0